Work Order Lookup

Date WO # Location Description Requester Status
11/2/2023 322887 GENERAL ASC 1 Get an estimate to install a new metal cap on the roof John Breon Assigned
7/9/2024 375652 GENERAL ASC 1 EXH-29 motor is bad chief operator Power plant Assigned
8/5/2024 381304 0171 ASC 1 Attn: JLamb call back 3 Aug AHU-11 threw a belt -belt was damaged did not locate a B-83 belt or find one at the store put the old damaged belted back on waiting for a new belt chief operator Power plant Assigned
8/16/2024 383398 0258 ASC 1 Graduate students complaining that the temperature in the office is 80 Brenda Brink Assigned
9/24/2024 390982 ASC 1 Hire Barron Equipment to replace dock lift. Assign to Anthony Gervais Anthony Gervais Open
11/13/2024 404128 D ASC 1 Applied Science BLD#1 - Upper Roof Section D Various Exhaust Roof Fans have tears in the canvas flex connections and need repaired. These are mainly located on the outlet side of the fan/discharge side. Thank you- Michael Fields Assigned
11/17/2024 404661 0111 ASC 1 ATTN: jlamb callback from Power Plant Operator- hood exhaust fan not working chief operator Power plant Assigned
3/3/2025 427126 0180D ASC 1 Fume hood down in 180D Moneim Ismail On Hold
3/14/2025 428599 0042 ASC 1 Applied Science 1 Building - Basement Level Above AHU 5 The first floor restroom 132-1 waste pipe that runs to the basement elevation has a large crack in the 4 inch cast piping that leaks water onto the AHU5 unit and the basement floor when toilets are flushed. A sign was posted on the restroom "Closed"... MF Michael Fields Assigned
3/24/2025 429488 ASC 1 Chilled water pump - differential pressure issues. Mark Schmitz Assigned
3/26/2025 429702 0280 ASC 1 Applied Science - AHU 9 AHU 9 is tripping out on high static alarm. Please verify if METASYS settings are correct for operation. Assign to Brian Angstrom... Thanks- MF Michael Fields Assigned
4/22/2025 435697 0042 ASC 1 3" Backflow failed testing, needs repaired. Lyle Bishop Open
4/24/2025 435969 ASC 1 ASC 1 - CT - REPLACE PARTS ON H550 PROMENIENT PUMP Brian Thilges Open
5/2/2025 441039 0141 ASC 1 Customers complaining about poor lighting in lab. Changed what bulbs I could. Ballasts need replaced. Needs some love. Thanks Ronald Rice Assigned
5/6/2025 441369 ASC 1 HEF 24 needs new bearings and fan shaft Michael Fields Materials-Awaiting
5/7/2025 441434 0243 ASC 1 The temperature in this room is uncomfortably cold. Melissa Twedt Assigned
5/19/2025 442385 GENERAL ASC 1 Power plant called me and said the DI water was not working. I went in to get it running. Joe Judge Assigned
5/19/2025 442398 0055 ASC 1 low DEIU pressure Michael Moore Assigned