Work Order Lookup

Date WO # Location Description Requester Status
3/1/2024 344781 0035 CO-LAB Exit sign was removed and paint touch ups are needed above door. Ryan Hurt Assigned
4/8/2024 355234 0016 CO-LAB Carver Co-Lab, Mech Room 16, 84 degrees Reheat may be leaking by Donald Boyle Assigned
4/29/2024 357826 0043 CO-LAB Co-Lab, Room Control, Basement BC, Room 43 reads 193 degrees 64B30, AI-1 Donald Boyle Assigned
5/6/2024 362205 0030 CO-LAB Reroute fire sprinkler drain pipe so it doesn't overflow the drain in basement room 0030 attn Tim Kelley Adam Pepper Assigned
6/5/2024 368769 1032 CO-LAB 1032 CCL - There is a small water leak from a pipe at the ceiling in this lab located just inside the main door. Peter Lelonek Assigned
7/15/2024 376177 CO-LAB Heat blowing out of west entryway. Barbara Heldt Open
8/13/2024 382880 0043 CO-LAB 0043 CCL - This room is cold even though the thermostat is indicating it is warm. I think the thermostat may be faulty. Peter Lelonek Assigned
8/28/2024 385434 0044 CO-LAB Co-Lab. Basement Electrical Room 44 80 degrees Not making set point SPT = 385 CFM CFM = 141 DMP = 100 % Open Donald Boyle Assigned
9/23/2024 390873 0016 CO-LAB Install Estop switch on outside of door. This is a permit blocking violation and needs to be done it the next 3-6 weeks. Please document with a photo so it can be sent the inspector. Anthony Gervais Open
10/24/2024 397747 1024 CO-LAB 1024 CCL - The eyewash in this lab is not working. Peter Lelonek Assigned
11/4/2024 403301 1016 CO-LAB Attn: Temperature Control Co-Lab, MR-1016 reads 100 degrees. See trend. Stuck at 100 degrees for months Donald Boyle Assigned
1/31/2025 417957 0122 CO-LAB Install Estop switch on outside of door. This is a permit blocking violation. Please document with a photo so it can be sent the inspector. Anthony Gervais Open
2/7/2025 421318 2007 CO-LAB 2007, 2031 and 2049 CCL - The mixing valves located under the sinks with eye washes in these 3 rooms are corroded and slightly leaking. We would like to get them repaired before they cause any major water damage. Peter Lelonek Assigned
3/26/2025 429664 2043 CO-LAB 2043 CCL - There is a light that is periodically flashing above the south sink in this room. Please repair the light and replace any other lights that are dim or out. Peter Lelonek Assigned
3/26/2025 429728 1010 CO-LAB 1010 CCL - There is a leak from a valve on a VAV box in this room. It is dripping onto a freezer. I can email a picture of the valve that is leaking if you tell me where to send it. This is a Select Agent room so the repair person will have to contact either Reuban Peters at rjpeters@iastate.edu or Meimei Xu at xumm@iastate.edu to gain entry. It would be nice if they had the repair parts with them so they only have to enter once. A ladder from 1016 was left in the room for their use. Peter Lelonek Assigned
3/27/2025 430388 0016 CO-LAB Storm drain piping system in sump corner room 0016 mechanical has been repaired previously in numerous areas. New leak has developed in horizontal drain pipe section with insulation overhead above pump control panel area and is leaking water onto floor. May need further repair or section replacement. Dale Headrick Assigned
4/16/2025 435279 0125 CO-LAB chamber 19 has a refrigerant leak attn chris grosz Christopher Grosz Assigned
4/21/2025 435635 0125 CO-LAB Follow-up verification of refrigerant repair. WO#435279 Anthony Gervais Assigned
5/1/2025 437191 0125 CO-LAB 0125 CCL - Growth chamber 19 is in alarm again due to overheating. Send card to Chris Grosz. Peter Lelonek Assigned
5/6/2025 441315 0028 CO-LAB 0028, 0122, 2032 CCL - I am told that none of the autoclaves in Carver Co-Lab in the 3 rooms listed are working. Peter Lelonek Assigned
5/6/2025 441320 2043 CO-LAB 2043 CCL - The light above the southern sink in this room is periodically flashing. It was turned in before but may not have been doing it when they came to fix it. Peter Lelonek Assigned
5/12/2025 441896 0004 CO-LAB Call back Attn Shane Clouser Urinal is running Shane CLOUSER Closed
5/19/2025
5/13/2025 442002 0122 CO-LAB 0122 CCL - The storm water pumping system appears to be leaking from the piping that is above the top of the floor as there is a lot of water on the floor in this area. Peter Lelonek Assigned
5/13/2025 442003 0030 CO-LAB 0030 CCL - the faucet on the sink in this room cannot be completely shut off. Peter Lelonek Assigned
5/13/2025 442007 0073 CO-LAB 0073 CCL - We have cleaned out this lab room for a new person who will be using it. Is it possible to have custodial clean and rewax the floor since it hasn't been done in a decade? Peter Lelonek Canceled
5/20/2025
5/14/2025 442093 1024 CO-LAB Attn Teemperature Control Carver Co-Lab, Lab 1024 temp is reading 171 degrees Alos the mech Room 1016 is reading 100 degrees Donald Boyle Assigned
5/20/2025 442569 0122 CO-LAB Replace floats and repair leak. Please assign to me. Donald Gregory Assigned