Work Order Lookup

Date WO # Location Description Requester Status
9/20/2024 390736 KENT FM Repairs to the north door in the Grain Center MMC Building Mickey McBride Open
10/9/2024 396472 1306 KENT FM A lot of condensate returning from the plant – both process steam and from the steam heaters (in the winter). The water temp goes above the set point and causes issues. Cleaver Brooks has responded that it is designed properly. Neither we nor T&S (which has followed up) agree. We need to find a workable solution for the steam condensate measurement system. We made a substantial investment in this system (incl electrical and BetaRaven programming) and need it running so Lexi can collect data to finish her M.S. Thesis research project. In our opinion, we need to add a bypass steam line (not a relief valve) that keeps steam pressure the same before and after the condensate measurement system without allowing condensate to flow through it. We think the way to do that is to add a parallel steam line that goes up perhaps 2-3 ft ahead of the high-level sensor (and after the closest steam trap) and reconnects to the high-pressure steam line below the condensate discharge valve. The key is for the line to go up first so that steam can follow that line while condensate keeps flowing into the measurement system line. This keeps the system closed, allows steam to bypass while condensate builds up, and will reunite condensate and steam after release to return to the feedwater tank. Mickey McBride Open
10/22/2024 397553 KENT FM Kent Feed Mill - 1873 State Avenue Outdoor Noise Monitoring Brady Harfst Open
4/4/2024 355030 KENT FM ATTN Joel Bender - Please provide quote for removing rock from grassy area. Camille Schroeder Assigned
4/4/2024 355032 KENT FM ATTN Joel Bender - Please provide quote to treat driveway for weeds. Camille Schroeder Assigned
11/11/2024 403935 KENT FM Finish seeding and mulching sewer route to the creek. Use socks or silt fence where needed. Mickey McBride Open
12/19/2024 411275 GENERAL KENT FM troubleshoot feed mill boiler failures attn chris grosz Christopher Grosz Assigned
3/13/2025 428552 1000 KENT FM Internal wiring has been damaged on the south facing entrance doors. This is sending constant break-in alerts to DPS Mickey McBride Materials-Awaiting
4/15/2025 435196 KENT FM MAV-1 shut off cant get running. Joe Flaherty Closed
4/23/2025
4/10/2023 272836 KENT FM Darrell Reeves Open
9/27/2024 392159 KENT FM Grading work that was needed due to winter to spring issues. Mickey McBride Open
8/11/2023 301811 KENT FM Miscellaneous Purchases-Reeves Toilet Accessories from Central Stores 13 EA-GOJO NXT MAXIMUM CAPACITY dispenser, 2000mL, black 2 EA- GOJO FMX-12 hair and body foam soap dispenser, dove gray 13 EA-Kimberly-Clark 09736 LEV-R-MATIC roll towel dispenser, translucent smoke grey 7 EA- Kimberly-Clark 09551 IN-SIGHT Cored JRT Combo Unit dispenser smoke/grey 5 EA- American Specialties, Inc (ASI) 0864-F surface mounted sanitary napkin/tampon dispenser 13EA - 23 Gallon Rubbermaid Slim Jim rectangular waste containers Darrell Reeves Open
4/11/2024 355546 KENT FM spray gravel areas at feed mill. Broom gravel from grass Joel Bender Open
9/26/2024 391408 KENT FM Swap motors on an existing fan. The motor is supplied by others. This work includes both electrical and millwright contractors. Mickey McBride Open