Work Order Lookup
| Date | WO # | Location | Description | Requester | Status |
|---|---|---|---|---|---|
| 8/4/2023 | 300984 | SCHEMAN | Scheman Building Renovation - Util Engineer | Caleb Barduson | Open |
| 11/19/2024 | 404788 | SCHEMAN | Call Back. DPS Called fire panel trouble. Attn Tim Kelley | Duncan Wood | Assigned |
| 11/25/2024 | 405302 | GENERAL SCHEMAN | Sprinkler head leaking Right before the mechanical room double door leading to basement. | Brent Williams | Assigned |
| 1/15/2025 | 415824 | SCHEMAN | COLD WEATHER BUILDING INSPECTION - SCHEMAN | Sailesh Gautam |
Closed 4/13/2026
|
| 6/2/2025 | 447207 | SCHEMAN | Barron Equipment inspection. | Anthony Gervais |
Closed 3/31/2026
|
| 6/5/2025 | 447572 | 0295 SCHEMAN | Need painting of multiple walls in the Brunnier Art Museum, including 2 large walls previously painted blue by FPM. In total, 3 large walls and 4-8 48" panel walls. Brunnier will provide specific paint color from Sherwin Williams. Date for work is July 29 - 30th. Additional location information: Brunnier Art Museum Work tags to attach: PG113015 DD16775 | Adrienne Gennett |
Closed 3/25/2026
|
| 6/6/2025 | 447856 | M0020 SCHEMAN | Check PRV and system pressure. East end of mechanical room. | Morgan Linley | Open |
| 6/21/2025 | 450253 | SCHEMAN | FY26 Snow Removal At Iowa State Center Lots (StandRenew) | FPM Service Desk | Open |
| 6/26/2025 | 451586 | SCHEMAN | Alarm on AHU 5 - Zone Humidity alarm - Check coupling or strainer on AHU 5 | Kimberlee Skelton | Assigned |
| 7/22/2025 | 460340 | M0020 SCHEMAN | Scheman Hall - Lower Level Mechanical Room M0020 The heating hot water hydronic pop off valve was popping off. This was dripping water down the piping insulation and onto the hot water pump 13. Need to verify expansion tanks are operating correctly. Sized correctly? Autofill valve operating correctly? The air and dirt separator is leaking dripping water on and through the insulation. This is a reoccurring problem. Phone number: 515-202-9450 | Tim Salasek | Materials-Awaiting |
| 7/29/2025 | 461228 | SCHEMAN | Lights out in rooms 004, 080, and 160. | Miles Pankonen | Assigned |
| 10/8/2025 | 479297 | 0004 SCHEMAN | Call back. Assist with system control. Attention Jeremy Forristall. Please assign to Jeremy Forristall only | Jeremy Forristall | Assigned |
| 10/10/2025 | 479539 | M0001 SCHEMAN | Attn Scott Nibe contractor stated there was a pump leaking water in Scheman. Thats all they gave me | James Bohl | Materials-Awaiting |
| 10/29/2025 | 481189 | SCHEMAN | Call Back, fire panel trouble attn Adam Pepper | Adam Pepper | Assigned |
| 11/5/2025 | 485494 | SCHEMAN | Elevator stuck on 2nd floor Schumacher Invoice 90660897 Technician found the pit flood switch float was tripped even though there was no water in pit. He cycled the switch, checked overall operation and returned car to service. .75 hour x $247.00 = $185.25 | Ryan Rieke | Open |
| 11/11/2025 | 485983 | SCHEMAN | Room 130 was really cold this morning. This is an ongoing issue every year. | Miles Pankonen | Assigned |
| 2/13/2026 | 503348 | M0020 SCHEMAN | Repairs to be made to backflow. Found on PM 373135. Updating from corrective WO 435739. Will work with buildings schedule for repairs. | Morgan Linley |
Closed 3/24/2026
|
| 2/16/2026 | 503450 | M0020 SCHEMAN | Repairs to be made to backflow. Asset number is E041449. | Morgan Linley |
Closed 3/24/2026
|
| 2/24/2026 | 504207 | SCHEMAN | Light under catwalk is hanging by its wires. | Morgan Linley | Materials-Awaiting |
| 3/2/2026 | 507936 | SCHEMAN | Sanitary line back up in Scheman and Elings buildings - Call Back for Cody Ryan | Craig Jensen |
Closed 3/26/2026
|
| 3/9/2026 | 508794 | SCHEMAN | replace photo cell attn holzmer | Mark Holzmer |
Closed 3/30/2026
|
| 3/20/2026 | 510340 | 0295 SCHEMAN | The museum space, exhibit, needs to be +/- 5 degrees from 70 degrees. Please adjust the temperature in the Brunnier Art Museum in the Scheman Building.. | Adrienne Gennett | Assigned |
| 3/30/2026 | 511376 | GENERAL SCHEMAN | Fire alarm panel backup batteries. Attn: Kevin Vols | Brett Shill |
Closed 3/31/2026
|
| 3/30/2026 | 511407 | SCHEMAN | Replace smoke detector 1st Floor Telecom Room. 4098-9601 Attn: Kevin Vols | Brett Shill |
Closed 3/31/2026
|
| 3/31/2026 | 511467 | GENERAL SCHEMAN | Attention Josh Bremer Call Back Scheman Museum Too hot in Museum. I flooded the cooling coil on the air handler I could access. I was in conversation with Museum staff about access and temperatures as well as forecasted temperatures. The other air handler cooling coil was flooded on Monday by Area Mechanics. | Joshua Bremer | Assigned |
| 3/31/2026 | 511469 | SCHEMAN | Update building fire alarm plat. Attn: Duncan Wood | Brett Shill | Assigned |
| 4/6/2026 | 515154 | SCHEMAN | Replace Power Supply | Steven Ristvedt |
Closed 4/7/2026
|
| 4/6/2026 | 515188 | SCHEMAN | ground level bathroom drains backing up | Lindsay Bertram | Open |
| 4/7/2026 | 515281 | SCHEMAN | The whole building is too hot. Auditorium, lobbies and rooms 167 -179. Please cool for today and bring back to normal temps tomorrow | Josh Oakland |
Closed 4/13/2026
|
| 4/8/2026 | 515380 | SCHEMAN | Need the fire panel taken down by 8 am so the kitchen vent hoods can be cleaned. Please take them down on 6/25 | Miles Pankonen | Assigned |