Work Order Lookup
Date | WO # | Location | Description | Requester | Status |
---|---|---|---|---|---|
5/24/2023 | 281510 | VDL | CP1119681-Utility Engineering-Vet Diagnostic Lab (VDL) Phase 2 | Michael Olson | Open |
8/9/2023 | 301633 | VDL | Daily bypassing of fire alarm panel. | Troy Chandler | Open |
11/30/2023 | 325385 | VDL | CP1119681-Utility Engineering-Vet Med VDL Phase 2-Purchase utility transformer | Michael Olson | Open |
3/12/2024 | 348755 | VDL | Perform necessary daily, weekly PM checks of building Equipment. Perform Walk-through of building equipment. | Lyle Bishop | Open |
3/20/2024 | 349353 | VDL | VDL Phase 2 - Contracted Services (Temporary Traffic Signal) | Caleb Barduson | Open |
4/22/2024 | 356415 | VDL | ATTN JLamb: Call Back from DPS- VDL low steam alarm | DPS dispatch DPS | Assigned |
4/25/2024 | 356824 | VDL | VDL Phase 2 - Metering | Caleb Barduson | Open |
4/25/2024 | 356827 | VDL | VDL Phase 2 - HV Electrician Support | Caleb Barduson | Open |
7/10/2024 | 375837 | VDL | VDL phase II construction utilities | Isaac Maffett | Open |
8/28/2024 | 385555 | 2010 VDL | FY25 VDL - SLA Additional Custodial Services | Katie Woodard | Open |
10/9/2024 | 396447 | GENERAL VDL | replace boiler water column union-steam leak-attn chris grosz | Christopher Grosz | Assigned |
11/1/2024 | 399339 | VDL | Create fire plats attn Duncan Wood | Duncan Wood | Assigned |
11/7/2024 | 403618 | VDL | VDL Phase 2 - Medium Voltage Switchgear Order | Caleb Barduson | Open |
1/10/2025 | 415248 | 1620 VDL | Replaced filter media in sand media filter. | Ryan Rieke | Open |
1/23/2025 | 416654 | 2500 VDL | in VDL 2500 at breakroom end of the science hall there is a -80 freezer that needs to have the power cord replaced. The unit is sticker IDd VDPAM-10315. I will attach the rest of the data for the unit, the instructions for accessing the power cord and the charge account in the comments later | John Beary | Assigned |
2/25/2025 | 423065 | 0519 VDL | Smoke coming out from Elevator Maintenance room. Technician found bad winding in the motor and a possible bad soft start. 3 Hours x $247.00 = $741.00 | Christine Crockett | Assigned |
2/28/2025 | 424038 | 1321 VDL | Remove existing pass thru window and frame. Paint and finish to match existing wall. | Troy Chandler |
Closed 4/3/2025
|
3/11/2025 | 428306 | 2526 VDL | Attn Joe Judge in VDL 2526 ATC8/V8518 has vacuum timeout issues. Joe requested that this SR get created. | John Beary | Assigned |
3/27/2025 | 430390 | 1620 VDL | Repair/Replace backflow preventer #64450. ( Note) I had requested this to be done the warranty punch list. Confirm Mike Moore. | Mark Deshong | Assigned |
4/1/2025 | 430780 | VDL | Call back-BEF-1A exhaust alarm | Tyler Pearson |
Closed 4/4/2025
|
4/1/2025 | 430781 | VDL | Call back-AHU 1 high static alarm | Tyler Pearson |
Closed 4/4/2025
|
4/1/2025 | 430782 | VDL | CALL BACK. VDL chillers/towers high infill pressure. ATTN: Joe Anastasi | Joseph Anastasi |
Closed 4/15/2025
|
4/2/2025 | 434099 | 1521 VDL | In the new VDL in rm 1521 there are issues with a couple of steam hose setups. An EHS employee sent me the following description. --- The long hose in the corner has steam, but the little relief valve doesn’t seem to be working, so it takes a while for the steam to start flowing. Not a huge deal. The shorter hose by the loading arm was working just fine this morning. . . until I tried turning the steam on. Not only did the steam not come on, but the water pressure to the hose has been reduced to nearly nothing. Turning the water off and back on doesn’t fix the issue. ------------ Please inspect and repair these issues | John Beary | Open |
4/7/2025 | 434462 | 2620 VDL | all 4 steam boilers in alarm, low water attn Chris Grosz | Christopher Grosz |
Closed 4/17/2025
|
4/7/2025 | 434477 | 2620 VDL | all 3 water boilers in alarm, high temp safety attn Chris Grosz | Christopher Grosz |
Closed 4/17/2025
|
4/8/2025 | 434605 | 1010 VDL | In the new VDL the bi directional hallway doors between the commons and tour hallway are alarming again after being properly carded. Please send someone to repair this issue as soon as possible. | John Beary | Materials-Awaiting |
4/9/2025 | 434804 | GENERAL VDL | Chilled water infill high alarm attn Chris Grosz | Christopher Grosz | Assigned |
4/10/2025 | 434861 | 2524 VDL | in VDL 2524 and appearently also the rest of upstairs at least, DI water isnt working at all. This is mission critical service so we need this repaired as soon as possible. | John Beary |
Closed 4/14/2025
|
4/15/2025 | 435131 | 2600 VDL | WATER TEMP ALARM ATTENTION JAMES SCOTT ROGERS. | James Rogers |
Closed 4/23/2025
|
4/15/2025 | 435157 | 1601F VDL | Push Button (physical plastic part) broken in front submissions office. | Carol Musser |
Closed 4/22/2025
|
4/16/2025 | 435315 | 1505 VDL | In VDL 1505 there is a light fixture out. This is an LED unit I will attach the Spec document for it after I create the SR. Please repair. This unit is on the VDL necropsy floor the tech will need escorted please check in at the front desk. | John Beary | Assigned |
4/16/2025 | 435334 | VDL | Call back-chilled water pressure alarm | Tyler Pearson |
Closed 4/21/2025
|
4/17/2025 | 435465 | GENERAL VDL | Attn James Long, Deric Anderson called me at 3:52pm Thursday 4/17 to tell me the boiler feed water was not keeping up with steam boilers. Diagnose and repair issues. | James Long | Assigned |
4/18/2025 | 435476 | 2603 VDL | LOW STEAM ALARM. | James Rogers |
Closed 4/23/2025
|
4/18/2025 | 435539 | 1528 VDL | Attn Joe Judge, in the new VDL all of the autoclaves crashed during their runs both upstairs and down. Is steam down currently? Please inspect ASAP. | John Beary |
Canceled 4/18/2025
|
4/18/2025 | 435554 | 2531 VDL | There is a DO leak in this room | Derick Anderson | Assigned |
4/21/2025 | 435625 | 1620 VDL | VDL Cooling tower spare belt | Gordon Woods | Open |
4/25/2025 | 436095 | 1022 VDL | Damaged cord on upright vacuum | Brian Anderson | Assigned |
4/28/2025 | 436796 | 1321 VDL | in VDL 1321 the humidity is at 55% the room is uncomfortable and the floors are wet. We need someone to look at this as soon as possible. | John Beary | Assigned |
4/28/2025 | 436887 | 1611A VDL | Strong odor from bathroom, multiple days of putting Consume and deodorizer down floor drain has not impacted smell | Brian Anderson | Assigned |
4/29/2025 | 436940 | 2620 VDL | VFD fault (Motor overload) in the Boiler room | Derek Anderson | Open |
4/29/2025 | 437011 | 0500 VDL | in the new VDL rm 500 there appears to be something wrong with the door sensors between this room and 400. We have received 11-12 DOTLs from velocity over the last 18 hours. Please inspect the door and repair the issue. | John Beary | Assigned |
5/1/2025 | 437223 | 2531 VDL | Attn Derick Anderson Order a pallet of salt for water softener | Derick Anderson | Assigned |