Work Orders in Gilman Hall
Showing all active work orders and all inactive work orders closed in the past 30 days.
WO # | Requested by | Description | Status |
---|---|---|---|
1940 | Lisa Ristvedt | Gilman Hall-Electrical Panel Replacement-Phase 2 | Open |
2075 | Lisa Ristvedt | Gilman Hall-Accessible Restroom Improvements | Open |
16672 | Kelly Kalvelage | WH30538 - Miscellaneous | Open |
16675 | Kelly Kalvelage | WJ34829 - Contracted Services | Open |
16678 | Kelly Kalvelage | WJ34830 - Builders Risk | Open |
97560 | Lisa Ristvedt | WH17782 - Miscellaneous | Open |
97561 | Lisa Ristvedt | WH17783 - Printing/Distributing Bidding Documents | Open |
105987 | Lisa Ristvedt | Gilman Hall-Renovation | Open |
105997 | Lisa Ristvedt | Miscellaneous | Open |
105998 | Lisa Ristvedt | Builders Risk | Open |
106007 | Lisa Ristvedt | Printing/Distributing Bidding Documents | Open |
140762 | John Netwal | This room has been recommended for a second means of egress to improve safety. A project scope and cost range were developed in 2015 to address this concern and may contain some helpful information. We would like this scope of work and cost range updated and reviewed with Troy Carey from EH&;S to verify it remains current with all current codes and recommendations. Previous 2015 project was PR018160. | Open |
140780 | Melissa Warg | FPM - FDC - PM - FEES | Open |
159429 | Lisa Ristvedt | Hazardous Material Abatement | Open |
159433 | Lisa Ristvedt | Miscellaneous Purchases | Open |
159434 | Lisa Ristvedt | Fixed Equipment | Open |
163544 | Michelle Grawe | This project will remodel the existing lab space. The project includes, but is not limited to, replacement of interior finishes, ceiling, electrical power, lighting, mechanical system components, plumbing lines and fixtures, and fixed casework. | Open |
164916 | Rachel Chunn | There are three doors that are not fully closing or latching. The students who lock the buildings at night can get the shut and locked but if anyone exits the doors after they have been locked they do not fully close or latch so they are not longer secured. The doors are: CX1620-2, CX1525, and X1C000 | Estimating |
173200 | Brad Lyons | ATT: Scott Nibe Drainage water pumps not working. | On Hold |
173885 | Kathleen Baumgarn | Please forward this to FPM Design. I cannot submit a request as the account link is not clear, so I cannot send it to them. Thanks for helping get this request to them. This general university classroom was identified as having inadequate ventilation and we have not been able to use the room since the start of COVID. We would like to have the ventilation issue investigated and a solution with possible costs created. Please issue this project to Brian Grove as he was working with Andrew Mott on some of my preliminary questions. Thank you! Katie B | Open |
173905 | Melissa Warg | FDC FEES - DO NOT CHARGE TIME | Open |
190980 | Joseph Burnett | There is a person stuck in the men's restroom. The door will not open. It is a swinging door. | Completed |
191406 | Lisa Ristvedt | Document Reviews | Open |
196180 | Mark Grief | Provide asbestos survey and rough order of magnitude estimate for portions of the 1914 original Gilman Hall. | Open |
196303 | Lisa Ristvedt | Document Reviews | Open |
196595 | Janet Schneider | AHU14, automatic valve on chilled water return line leaking | Materials-Awaiting |
196731 | Janet Schneider | high pressure steam leak above FTK2 | Materials-Awaiting |
197284 | Shane Nehring | Window Panes Cracked in 110 Gilman | On Hold |
198349 | John Breon | Old School to give estimate on tuck-pointing and brick replacement on South-Central roof area | Assigned |
199484 | Michelle Grawe | 0310 Gilman needs an eyewash | Open |
199801 | Mark Grief | Purchase eight [8] black Apco Frames, SH-88-A2, 8” H x 8” W, vinyl tape for rooms - R0752,R0754,R1232,R1752,R2232, R2752, R3232, R3752. | Open |
200619 | FPM Service Desk | FY23 Annual Maintenance for Emergency Power Generator - Gilman - E017969 | Open |
200992 | FPM Service Desk | FY23 GILMAN - General Cleaning | Open |
202236 | FPM Service Desk | FY23 GILMAN - Supplies | Open |
204440 | Theresa Dropps | Gilman Hall-Wayfinding and Signage-Improvements | Open |
204492 | Theresa Dropps | Hazardous Material Abatement | Open |
204532 | Theresa Dropps | Miscellaneous | Open |
205950 | Jessica Archer | Need new blinds they are bent and broken | Completed |
206063 | Paul Engelken | Attn. Gene, weld-let on chilled water return needs repaired. | Assigned |
206850 | Michelle Grawe | Remove the center island/desk, and replace it with materials we have in storage. We have soapstone countertops and supports in storage that we would like to place in the center of the room. | Open |
206863 | Melissa Warg | FDC FEES - DO NOT CHARGE TIME | Open |
208683 | Michelle Grawe | Multiple cabinets need to be repaired. PI would like the cabinets painted (they have the paint). They also want a drain system for their polishers installed. This would be a PVC pipe that would run behind their polishing equipment and then connect to the drain in the island. | Open |
208706 | Scott Jasper | FDC FEES - DO NOT CHARGE DESIGN TIME | Open |
216312 | Mickey McBride | Parking passes for Gilman Hall project | Open |
216698 | Mickey McBride | Owner Supplied Restroom Accessories 2 each paper towel dispensers 3 each toilet paper dispenser 2 each under-counter waste bin 3 each soap dispenser 1 each sharps container | Open |
218542 | Anthony Gervais | Needs new group 31 battery due to failing load test. Attn Derick Anderson | Open |
218669 | Adam Pepper | Duct detector output abnormal att apepper | Completed |
218788 | Mark Grief | Provide assistance related to moving items from 1241 to 1162 in Gilman Hall. | Open |
222978 | Jeffrey Lamb | Attn; Jeremy or Dana - AHU 17 supply fan A VFD in alarm for power loss will reset and every time you start it in local or auto it goes back in power loss alarm, checked fuse - all good and power - good | Assigned |
223426 | Paul Engelken | Attached. Todd have 4" steam wyes strainer replaced | Assigned |
223428 | Paul Engelken | Attached. Todd, have have steam trap and line replaced. | Assigned |
224527 | Joe Judge | Replace 16 P-traps in room 3206 Gilman Hall with plastic ones. This is a chemistry lab and they are all showing signs of leaking. | Materials-Awaiting |
226047 | Lyle Bishop | Hire HM Cragg to repair 2 wires in control panel, replace batteries, replace upper and lower radiator hoses, replace thermostat and coolant on emergency generator. ATTN: Lyle Bishop. | Completed |
230462 | Michelle Grawe | The lower fume hood baffle in the back of the fume hood is broken in two spots | On Hold |
231084 | Lyle Bishop | Change oil and filter on Emergency Generator. ATTN: Derick Anderson. | Assigned |
231085 | Lyle Bishop | Change oil and filter on Emergency Generator. ATTN: Derick Anderson. | Assigned |
231125 | Lyle Bishop | Change coolant on Emergency Generator. ATTN: Derick Anderson. | Assigned |
231126 | Lyle Bishop | Change coolant on Emergency Generator. ATTN: Derick Anderson. | Assigned |
237978 | Brian Angstrom | ATTN Dana Wills - VFD10B | Materials-Awaiting |
238152 | Michael Richards | Contracts | Open |
238234 | David Appy | High air flow through slot in ceiling (last few days). Stopped briefly this morning. Please check. | On Hold |
238235 | David Appy | Radiators not on in Gilman 3751-3762 offices. | On Hold |
239789 | Eric Ohrt | Contracts | Open |
239792 | Paul Engelken | Attn. Brad plate exchanger leaking | Completed |
241069 | Michael Richards | Contracts | Open |
241230 | Janet Schneider | AHU11, replace isolation valves for chilled water coil, there are 2 that would not close completely, but we would like all 10 replaced, they are hard to turn on and off. see Janet for location | Assigned |
245863 | Michael Fields | Expansion tank ETK5 located in the open ceiling space of room M0778 (east side of the room) has a piping leak at the union between the air separator ASU09 and the ETK5 unit. (Piping threads going into the union are very rusty) | On Hold |
245974 | Michael Wilson | Door with supplemental instructions paper slams when opening and letting it close. It is inconsistent. | On Hold |
246317 | Michael Fields | The following Gilman Hall safety shower (on/off pull) valve handles do not operate smoothly: Room 0801 - shower ESH15 and Room 0804 - shower ESH12. | Materials-Awaiting |
246320 | Michael Fields | Safety Shower ESH117 in Room 3801 Gilman Hall - on/off pull handle does not operate valve assembly smoothly. | Materials-Awaiting |
246411 | Valerie Roark | Faucet handle is loose. Has been marked. | Completed |
246580 | Michael Mosch | door at the top of the stairs, to access roof section C, in the SE corner of Gilman, will not open and needs weather stripping . It says RM 4820 on the door. | On Hold |
251188 | Eric Ohrt | Intramural to parking | Open |
251691 | Abigail Zumpano | Contracts | Open |
251694 | Abigail Zumpano | System Controls Support | On Hold |
252120 | David Appy | The Chem Department would like to request another rough estimate for renovations as part of on ongoing hire negotiation. Time is of the essence. We would potentially renovate Gilman 2651 for use a cell culture room. It will need, at minimum: New floor. New cabinetry. Electrical setup for freezer/biosafety cabinet, at least. Likely instrumentation around edges. I am available tomorrow, 1/13 at 2 pm for certain. Otherwise please suggest a time to meet, and thanks again. -David Appy (dvappy@iastate.edu) | Open |
252136 | Melissa Warg | FDC MGMT FEES - DO NOT CHARGE TIME | Open |
253236 | Lyle Bishop | Troubleshoot Fire Alarm Panel Deficiencies. Card one positive earthground on main panel. Horn/Strobe by 1202-2 short circuit trouble on nac panel. no horn & no strobe. 4903-9255. Horn/Strobe H0701 by M1164, short circuit trouble on 4009 nac panel. no horn & no strobe. 4903-9255. Horn/Strobe H0801 by M0151, no strobe 4903-9255. Smoke in stairwell CS4236 by room M4233 M4-55, no answer 4098-9714 and 4098-9792. Replace aged out battery in NAC panel room CC4230, 12v 10amp part SLA 1097. | Open |
254775 | Abigail Zumpano | IT Intramural | Open |
254778 | Abigail Zumpano | Printing Intramural | Open |
254779 | Abigail Zumpano | Parking Intramural | Open |
258306 | Paul Engelken | Remove and replace condensate trap and piping | Completed |
259203 | Michelle Grawe | The PI for this lab is wondering if there is a way to get a 3-phase outlet with a JL04HV-2E22-22PE-B-R connection that can provide 380-440V in this lab for a new piece of equipment he is purchasing. | Assigned |
259419 | Josef Biechler | Asbestos monitoring | Open |
259520 | William Webster | Remove and replace leaking gate valve on pumped condensate line. | Completed |
259549 | Tyler Pearson | Water Leak in Hall Near Room 3157 | Completed |
259623 | William Webster | Replace float on drainage pump. | Completed |
260017 | Kathleen Baumgarn | The demonstration bench in Gilman 1002 has a damaged sink and table top. We need an entirely new integrated chemical resistant sink and table top, as well as a new cabinet. This is highly used for the Chemistry class demonstrations. All of the current utilities will need to remain in the cabinet, including AV storage with ventilation. There is a down draft 'hood' in the bench too. This project is going to be paid for by three sources: FPM - Andrew Mott: PG100344 DD03416 Room Scheduling - Katie Baumgarn: PG100358 DD14556 LAS College - Robin Jones: PG100170 Please DO NOT charge 100% of this project to my account that is provided below...it is only 1/3 of the total costs. This replacement must be completed by August 4, 2023. Thank you for getting started on this right away. Katie B. | Open |
260340 | Jessica Archer | Window won't stay shut. There is also access to the roof from this window. In staircase cc2050. It is in between 2nd and third floor. | On Hold |
260432 | Melissa Warg | FDC MGMT FEES - DO NOT CHARGE TIME | Open |
260548 | Brian Angstrom | Attn Dana Wills repair/replace AHU #15 VFD | Materials-Awaiting |
261388 | Shan Jiang | it is very hard to open the entrance door at the 3rd floor stairway to the hall way, at the east/south corner of Gilman building. Phone number: 5152941445 | Materials-Awaiting |
265134 | Brad Lyons | ATT: Dale lutter Reinsulate heating water lines after repairs were made. See Brad Lyons for more information. | Assigned |
265171 | Eric Ohrt | Parking Intramural | Open |
265232 | David Appy | Gilman-Hach Tunnel. We would like to have the two tunnel doors equipped with remote opening mechanisms, to assist people with carts. Design choice would be with this functionality in mind. Please contact David Appy for questions. dvappy@iastate.edu | Open |
265237 | Melissa Warg | FDC MGMT FEES - DO NOT CHARGE TIME | Open |
265295 | Mark Grief | Work Order for JCI Design | Open |
265332 | Abigail Zumpano | IT intramural | Open |
265441 | Abigail Zumpano | Contracts | Open |
265444 | Abigail Zumpano | Fire Alarm Support | On Hold |
265800 | Michael Fields | Heating Water, Hot Water Strainer on Supply Line Needs Replaced | Completed |
266026 | Bill Seliger | In Gilman hall room 3758 there are 5 ceiling tiles that need to be replaced. 3831 has 3 ceiling tiles to be replaced. In hallway outside of room 3285 2 ceiling tiles to be replaced. In hallway outside of room 3252 1 ceiling tiles to be replaced. Hallway outside of room 3242 1 ceiling tiles to be replaced. Hallway outside of room 3802 3 ceiling tiles to be replaced. Hallway outside of room 3158 has a ceiling hatch that needs to be closed. | Assigned |
266053 | Todd Kelley | 4" sanitary cast drain pipe M0078 Todd Kelley | Open |
266368 | Eric Ohrt | Hire asbestos contractor to remove pipe insulation | Open |
266567 | William Webster | Repair cracked sanitary drain line and fittings. | Completed |
266707 | Bill Seliger | In Gilman hall M3238 there is a MasterCraft wet/dry vac the drain will not close needs repaired. E023038 is the equipment tag number. | Materials-Awaiting |
266810 | Susan Cross | I need an estimate for renovations and some light construction (open cubicles) for Gilman 2216 along with furniture for using that space as a lab. I can send a configuration and list of furniture. Worktag: PG103909-DD10954. | Open |
266812 | Melissa Warg | FDC MGMT FEES - DO NOT CHARGE TIME | Open |
266906 | Jessica Archer | Lights out 2 next to 2205-1 1 next to 2156-4 1 next to 2159 1 next to 2156-1 1 next to 2101 2 next to 2835-1 2 next to 2758 2 next to 2756 1 next to 2734 | Assigned |
266907 | Jessica Archer | Ceiling tiles are missing in hallway 5 tiles next to room 2057 4 tiles next to room 2109 1 tile next to room 2835-1 1 tile next to room 2808 1 tile next to womens restroom R2752 1 tile next to stairway cs2236 1 tile next to room 2231 1 tile next to room 2708 1 tile next to room 2710 1 tile next to room 2551 1 tile next to room 2631 2 tiles next to room 2251 1 tile next to hallway cc2200 | Assigned |
268077 | Bill Seliger | In Gilman hall room R3752 there is 1 light fixtures that need bulbs replaced | Assigned |
268137 | Eric Ohrt | Casework order | Open |
272194 | Gene Leamen | Replace leaking air separator Attn Gene Leamen | Assigned |
272207 | Michelle Grawe | 3305 Gilman west island, south faucet vacuum breaker needs to be replaced since the water leaks out of the top of the faucet East island one faucet is loose Next door in 3311, the west sink vacuum breaker needs to be replaced. | Assigned |
272244 | Michelle Grawe | 3305 and 3311 have light bulbs that are out and need to be replaced. Also, the existing lightbulbs flicker randomly and hum, so they may also need to e replaced. We can't figure out which lights are humming. | Assigned |
272258 | Bill Seliger | In Gilman hall room 3282 there is 1 light fixtures that need bulbs replaced | Assigned |
272992 | Jessica Archer | It is very hot in stairwell cx1620 heater just keeps running and won't turn off | Assigned |
273042 | David Appy | 1002 lecture hall too hot. | Assigned |
273044 | David Appy | Northeast Gilman stairwell (1600's wing) extremely hot. | Open |
273104 | Robert Currie | space uncomfortable cold during current hot weather | Open |
273154 | Jittaun Townsend | Bathroom light is out R1303 | Assigned |
273218 | Brett Boote | Room 0661 in Gilman runs quite warm, and the setpoint on the wall is showing 86*F. Blowing hot air out of the ventilation. Please decrease the setpoint to something manageable. Phone number: 13098386155 | On Hold |
273366 | Michael Hanson | Replace broken actuator on South set of chilled water coils on AHU. 11 | Assigned |
273379 | David Appy | 1114 Gilman - Install Periodic Table on south wall (door-side) above the chalkboard. *We have recently done similar things in the 1800's wing of Gilman. The same template would work, if it is available. Please contact David Appy for questions. dvappy@iastate.edu | Open |
273382 | Melissa Warg | FDC MGMT FEES - DO NOT CHARGE TIME | Open |
273565 | Janet Schneider | There has been a weird noise that might have something to do with the VAV Heating Control valves. Janet and Mike have been trying to figure out the noise that seems to be happening in this room. If any questions feel free to call them. | On Hold |
273666 | Barbara Brown | Office is too hot, the heater also makes too much noise. It sounds like it is grinding gears. It makes this noise all year long. | Materials-Awaiting |
273886 | Bill Seliger | In Gilman hall room R3232 there is 1 light fixtures of bulbs that need replaced | Assigned |
273904 | Bill Seliger | In Gilman hall room 3304 there are 2 light fixtures that need bulbs replaced. 3304A there is 1 light fixtures need bulbs replaced | Assigned |
273909 | Bill Seliger | In Gilman hall room 3053 there is 1 light fixtures need bulbs replaced. 3053A 2 light fixtures need bulbs replaced. 3053B 1 light fixtures need bulbs replaced. 3053C 2 light fixtures need bulbs replaced. 3053D 1 light fixtures need bulbs replaced. Hallway outside of 3053 2 light fixtures need bulbs replaced. | Assigned |
273910 | Bill Seliger | In Gilman hall room 3104 9 fixtures need bulbs replaced | Assigned |
273911 | Bill Seliger | In Gilman hall room 3111 1 light fixtures need bulbs replaced | Assigned |
273912 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273917 | Bill Seliger | 2 light fixtures need bulbs replaced. Hallway outside of 3153 1 light fixtures need bulbs replaced | Assigned |
273919 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273921 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273922 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273923 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273924 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273927 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273928 | Bill Seliger | 3 light fixtures need bulbs replaced | Assigned |
273930 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273933 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273938 | Bill Seliger | 11 light fixtures need bulbs replaced | Assigned |
273940 | Bill Seliger | 4 light fixtures need bulbs replaced | Assigned |
273941 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273942 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273943 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273944 | Bill Seliger | 2 spot light fixtures need bulbs replaced | Assigned |
273945 | Bill Seliger | 5 light fixtures need bulbs replaced | Assigned |
273946 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273947 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273948 | Bill Seliger | 1 light fixtures need bulbs replaced | Assigned |
273950 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273952 | Bill Seliger | 4 light fixtures need bulbs replaced | Assigned |
273953 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273954 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273955 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
273956 | Bill Seliger | 2 light fixtures need bulbs replaced | Assigned |
274844 | Jessica Archer | Light out in mens room | Assigned |
274868 | Matthew Grabau | by room 0656 by room 0610 by room 0611 | Assigned |
274881 | Matthew Grabau | ceiling tiles by rooms by 0201,0201-a between rooms 0203 & 0207 by room 0213 by room r0303 by room 0312 by cc0630 by room 0635 by room 0755 by room 0757 by room 0774 by room 0780 | On Hold |
279222 | Ryan Braga | lab at about 90F | Open |
279315 | Ryan Braga | significant % of lights not working in room | Assigned |
279317 | Ryan Braga | number of lights out in hall | Assigned |
279503 | Tyler Wirth | Flush valve is leaking on urinal. Attention Tyler Wirth | Completed |
279564 | David Appy | Restroom door slams. | Estimating |
279586 | Savannah Betts | Overhead light in first floor maintenance closet (M1164) is burnt out/not working. | Assigned |
279590 | Sarah Kallsen | the heater heater in my office is making a loud noise (like water running). It's also continuously running heat. I think someone should come take a look at it? | Assigned |
279600 | Abigail Zumpano | Demo old plumbing for new cabinet and reinstall new plumbing once new cabinet arrives. Attn: Clouser | Assigned |
279672 | Savannah Betts | light in stall of accessible men's room has burnt out | Assigned |
279737 | Savannah Betts | Two overhead lights burnt out down C1700 near x-ray labs | Assigned |
279865 | William Webster | Check for ACMs in connection with job # 279758 Standing seam metal roof - Contractor to inspect and provide estimate for repairs Roof Chimney Stack | Open |
279870 | Michelle Grawe | Fume Hood E033583 is not working properly; the damper above it seems to be malfunctioning. As soon as the sash is lifted even a few inches, the fpm drops to 60 fpm, and the alarm sounds | Assigned |
279993 | Savannah Betts | exit sign on interior side of hall has no lights | Assigned |
280012 | Bill Seliger | In Gilman hall room 3053 B there is a cracked window that needs repaired. | Assigned |
280027 | David Appy | Strip and wax grad lounge. (work order requested by Jess (custodian)) | Open |
280037 | Reed Jensen | Too Hot with No Flow in the Machine Shop | Assigned |
280053 | Todd Kelley | Replace Concrete house keeping pad (Reiley)$2500 | Open |
280120 | Tristan Verkade | Replace missing and damaged ceiling tiles. | Assigned |
280221 | Todd Kelley | Replace 4'' cast sewer line off hours carpenter to follow Todd Kelley | Completed |
280238 | Ryan Braga | report that hvac is blowing hot air into the lab. room is warm | Assigned |
280250 | Savannah Betts | Light bulbs in 2nd and 3rd lights away from Natl Lab door are burnt out (not all just one in each) | Assigned |
280448 | William Webster | Replace leaking 12" low pressure steam pipe. | Completed |
280597 | Valerie Roark | Loose faucet handles in 0284, 0610 and 0652. Lab 1352 has 2 of 3 Faucet missing aerators and the 3rd faucet has no water. | Assigned |
280636 | Sherri Paul | Too Hot per call from occupant (607-882-0673) | Assigned |
280799 | Trond Forre | Annealing Oven Needs New Cord/Plug (3-phase) | Assigned |
280954 | Lisa Smith | There are 4 sections of lights burnt out in the office area of 1605 Gilman Hall that we would like replaced. | Assigned |
280994 | JENA WENCK | FOUND SOME PAINT GRAFFITI ABOVE FIRST FLOOR ON SOUTH SIDE OF BUILDING KIND OF TUCKED IN AN INNER COURT YARD.SPRAY PAINTED CARTOON CAT. AREA WAS ACCESSED THROUGH A WINDOW IN BETWEEN THE SECOND AND THIRD FLOOR. THE WINDOW IS BROKEN. THE VANDALISM IS INSIDE THE STAIRWELL S2010, THE WINDOW IS NOT SECURED. THE GRAFFITI LOOKS LIKE A LITTLE PURPLE RABBIT. IF YOU GO OUT THE WINDOW AND DOWN THE LADDER AND TO THE WEST IT IS ON THE WALL DIRECTLY TO THE SOUTH. ISU REPORT NUMBER 23-000542 | Assigned |
281062 | Michelle Lenkaitis | Painting needed where ceiling leak occurred in corridor near room 0774 (not listed in Building Room list). See attached photo. | Assigned |
281080 | Ryan Braga | lab very hot | Assigned |
281126 | Bill Seliger | In Gilman hall room 3206A there is some mop board that needs to be reglued. | Assigned |
281130 | Nikole Dufelmeier | Stripping and waxing | Open |
281186 | Kimberlee Skelton | Generator in alarm status for node room of Gilman | Assigned |
281270 | Troy Rutter | Hello, can you please verify that my office space, GILMAN 2659B, has been set for summer temperatures? I think I had a manual override on over the winter and the minimum/optimal temperature may be set fairly high. Thank you. | Assigned |
281299 | Donald Gregory | Repair chilled water pump | Completed |
281319 | David Appy | 1605D - Occupant (Angela Harms, 294-6343) would like some pictures hung on the walls. | Assigned |
281362 | Darrel Enyart | Have Locknetics lock taken from a lab in Hoover that we want to be installed on the door to 0305 Gilman. Want the current lock cylinder in the door of 0305 installed in the Locknetics lock. Our department can handle the programming of the Locknetics lock once it is installed on the door. | Open |
281398 | Brad Lyons | Remove and replace air/dirt separator on heating water system | Completed |
281435 | Matthew Grabau | pipe leaking | Assigned |
281446 | Barton Dobson | Remove men's restroom sign from room R1232 and relocate it to room 1241. | Open |
281454 | Jessica Archer | Autoscrubber is located in hach hall at the moment. Went to use it smelt like something was burning looked at the batteries and there was stuff leaking out. E063065 | Materials-Awaiting |
281472 | Barton Dobson | Stock and final clean restroom R1241 | Open |
281477 | Angela Harms | Ceiling is leaking water in 1605 Suite | Assigned |
281560 | Christopher Grosz | investigate roof and flashing above central elevator. Attn John Breon | Assigned |
282289 | Bill Seliger | In Gilman hall room R3752 there is a light fixture out over the sink | Assigned |
282342 | David Appy | Light sensor vibrates/shakes. Possibly due to connection to air duct. Please take a look. | Assigned |
282346 | Michael Mosch | A glass pane is broken out of the window and needs replaced. | Assigned |
282394 | Lisa Smith | The right-hand side lock for the graduate student photo display case is broken. There is a key to the photo display in 1605 Gilman Hall. When looking at the photo displays the left-hand side key works perfectly, but the right-hand side key only turns and turns without doing anything. | Assigned |